Description
Install Manual
Intermatic T7401BC 7-Day Mechanical Time Switch, 120 VAC, 60Hz, 4-SPST, Indoor Metal Enclosure, 3.5 Hour Interval
These 7-Day Mechanical Time Switches offer the capability of having a different schedule for each day of the week. They can handle up to 40 A of electrical loads per circuit and have separate terminals for powering the clock motor. These time switches can handle up to four loads per clock, providing a single control for easier installation. Each time switch comes with 7 ON and 7 OFF trippers, allowing for at least one ON/OFF operation each day.
Features:
- Different ON/OFF programs each day of the week
- True 7-day load control with minimum ON/OFF time of 3 1?2 hours
- Separate clock motor terminals for switching loads not on line voltage
- Carry-over automatically rewinds when power resumes
- Minimum of 16-hour carry-over for maintaining preset schedules during power failures
- Available with Type 3R rated outdoor metal enclosure or Type 1 rated indoor metal in gray finish with separate grounding terminal
Applications:
-
Indoor Lighting Control
-
Timing/Scheduling ON/OFF
Specifications:
Backup Type | Spring Wound Carry-over | Input Voltage Range(s) | 120 VAC, 60 Hz |
Maximum ON/OFF Operations | 28 | Number Of Circuits | 4 |
Operation Mode | 7-day | Resistive | 40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz, 40 A, 480 VAC, 60 Hz |
Switch Type | 4-PST/NO | Electronic Ballast | 16 A, 277 VAC, 60 Hz |
Enclosure Type | Indoor type 1 metal | Minimum ON/OFF Times | 3.5 hours |
Maximum Power Consumption (W) | 3 W | Wiring Option | Terminals |
Resistive Load Ratings Ranges | 40 A, 120-480 VAC, 60 Hz | Backup Protection Time | 16 Hours |
Warranty Period | 1-Year limited | Application Compatibilities | HID, LED |
Backup Restoration Time | 1 Hour for Every 2 Hours Without Power | Electronic Ballast Load Ratings Ranges | 16 A, 277 VAC, 60 Hz |
Has Manual Override | Yes | Inductive | 40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz |
Inductive Load Ratings Ranges | 40 A, 120-277 VAC, 60 Hz | Motor (Single-Phase) | 2 HP, 24 FLA @ 120 VAC, 60 Hz, 5 HP, 28 FLA @ 240 VAC, 60 Hz |
Motor (Three-Phase) | 10 HP, 28 FLA @ 240 VAC, 60 Hz, 7 1/2 HP, 28 FLA @ 208 VAC, 60 Hz | Motor Single Phase Ranges | 2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz |
Motor Three Phase Ranges | 7 1/2 HP, 28 FLA @ 208 VAC, 60 Hz; 10 HP, 28 FLA @ 240 VAC, 60 Hz | Pilot Duty (NO) | 1000 VA, 120 VAC, 60 Hz, 1000 VA, 208 VAC, 60 Hz, 1000 VA, 240 VAC, 60 Hz, 1000 VA, 277 VAC, 60 Hz |
Pilot Duty Load Ratings Ranges | 1000 VA, 120-277 VAC, Per Pole, 60 Hz | Rating | General Purpose |
Skipper Wheel | Not Included | Timer Type | Mechanical |
Tungsten (NO) | 40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz | Tungsten Range(s) | 40 A, 120-277 VAC, 60 Hz |
Wire Size Max | #8 AWG | Wire Size Min | #14 AWG |
Operating Temperature Max (°C) | 54 | Operating Temperature Max (°F) | 130 |
Operating Temperature Min (°C) | -40 | Operating Temperature Min (°F) | -40 |
Product Depth (in) | 3.75 | Product Depth (mm) | 95.25 |
Product Height (in) | 13.125 | Product Height (mm) | 333.3 |
Product Width (in) | 9 | Product Width (mm) | 228.9 |
Unit Carton Height (in) | 6.75 | Unit Carton Length (in) | 15.75 |
Unit Carton Weight (lb) | 10.001 | Unit Carton Width (in) | 11.75 |